New Release v2.0

GW-LR60 Protection and Control Device

Protection FunctionsCurrent Protection: 50P-1/2/3, 50P, 51P, 50N, 51N, 46, etc. Voltage Protection: 59PR, 27PR, 81O, etc. Power Protection: 32P, 25, 79, SOTF AR Protection Monitoring: CT Monitor, LOP, 74TC, etc. Load Protection: Too long starting time protection, Overheat protection, LR, etc. Loggin

Industry Certifications & Standards

verified_user

ISO 9001

Quality Management

CE

Certified

EU Compliance

scale

MID

Measuring Instruments

recycling

RoHS

Hazard-Free Materials

workspace_premium

IEC 62053

Metering Accuracy

UL

Listed

Safety Standard

Ready to move forward with your next power project?

Our engineering team will review your technical requirements and provide the right solution.

Share your drawings or specifications to get a customized project proposal.

About the Power Meter

The digital power meter provides accurate measurement, reliable performance, and flexible functions for power monitoring and energy management.

Parameter Value
Power Supply 88~264V 50/60Hz AC/DC universal; DC24V; DC48V
CT Nom/IX 5A, 1A
IN, CT Nom 1A
AC Nom 100V (line voltage)
System Freq 50Hz/60Hz
Power consumption AC current loop 5A configuration, no more than 1VA/phase; 1A configuration, no more than 0.5VA/phase; AC voltage circuit no more than 0.5VA/phase; Working power circuit no more than 5W
Voltage/Current ±0.5%
Active/Reactive Power ±0.5%
Frequency ±0.01Hz
kWh Import/Export Grade 1
kvarh Import/Export Level 2
Connection capacity 5A continuous; 30A, 0.2s
Action time < 10 ms
Return time < 5 ms
Breaking capacity DC with resistance of 50W; Perceptual 50W (L/R = 0.04s); AC 1250VA, max. 5A
Switching value input 220VDC/AC, 110VDC/AC, 24VDC and 48VDC optional
Operating Temperature -25 ~ +70℃
Storage Temperature -40 ~ +85℃
Atmospheric Pressure 70 kPa~110 kPa
Relative humidity 5% ~ 95% (no condensation or freezing inside the product)
Above sea level ≤ 3000m
Electrical Insulation IEC 60255-5 (GB/T 14598.3), 2kV@1 minute
Insulation resistance >100MΩ/500V AC
Electrostatic Discharge (ESD) Immunity Test Level 4
Fast Transient Burst (FTB) Immunity Test Level 4
Surge (Transient Overvoltage) Immunity Test Level 4

Product Overview

The GW-LR60 protection and control device is a new-generation relay protection product developed to meet the requirements of modern power systems. It provides comprehensive protection functions for primary equipment at 35 kV and below, including lines, transformers, motors, capacitors, and feeders.

The series is built around an industrial-grade microprocessor and integrates high-precision CT/VT modules, high-insulation output relays, and a highly reliable switching power module. It features high integration, comprehensive protection configurations, strong anti-interference performance, low power consumption, and robust environmental resistance, while supporting convenient on-site maintenance and commissioning. The devices can be installed in distributed configurations on switch cabinets or configured in screen-mounted setups.

Anatomy of Precision

Protection Functions

Current Protection: 50P-1/2/3, 50P, 51P, 50N, 51N, 46, etc.

Voltage Protection: 59PR, 27PR, 81O, etc.

Power Protection: 32P, 25, 79, SOTF AR Protection

Monitoring: CT Monitor, LOP, 74TC, etc.

Load Protection: Too long starting time protection, Overheat protection, LR, etc.

Logging & Time Synchronization Functions

Supports categorized query of 256 event records; data retained during power loss

Supports software time synchronization; internal clock error ≤ 1 s per 24 hours

Supports the call of WR data

Measurement Functions

Supports primary/secondary measurements

Supports forward/reverse active & reactive energy

Supports voltage, current, frequency, power, and power factor, etc.

Communication Functions

Standard 1× RS-485 communication interface (P1 port)

Supports Modbus-RTU industrial protocol

3 voltage inputs, 4 current inputs

9 DI, 5 DO

Supports remote control operation

Compliance Information

GR-LR60-G fully compliant with applicable EU directives and standards.

Application Fields
GR-LR60 has rich and comprehensive protection functions, and is applicable to various medium and high voltage power systems, and can be used for:

Distribution transformer protection

Capacitor protection

Bus section protection

Feeder protection

Motor protection

Backup protection for various electrical equipment

Cutout Dimensions and Installation Diagram (Unit: mm)

158a3dff8a6add214e9b0ea3de7a2552.png

ced38ece5959ca6d5e77be0c023961bc.png

Related Products

VoltMeter Mini product example image
New

VoltMeter Mini

Compact DIN-rail single phase meter for residential use.

View Product arrow_forward
Comms Hub X2 product example image

Comms Hub X2

Industrial IoT gateway for multi-meter data aggregation.

View Product arrow_forward
CT Sensor Pack product example image

CT Sensor Pack

High-precision current transformers split-core design.

View Product arrow_forward
Remote Display product example image

Remote Display

External LCD panel for cabinet door mounting.

View Product arrow_forward

Ready to upgrade your infrastructure?

Contact our sales team for bulk pricing or request a demo unit to test in your facility.