New Release v2.0

GW-LR51-G Anti-Islanding Protection Device

Protection FunctionsCurrent Protection: 50P-1/2/3, 50P, 51P, 50N, 51N, 46, etc.Voltage Protection: 59PP, 27PP, LOP, etc.Control & Monitoring: CT/Control Circuit Disconnection, DI Trip, etc.Reclosing Control: 79 Auto-reclosing, SOTF AR, Standby Auto-injection Block, etc.Logging & Time Synchro

Industry Certifications & Standards

verified_user

ISO 9001

Quality Management

CE

Certified

EU Compliance

scale

MID

Measuring Instruments

recycling

RoHS

Hazard-Free Materials

workspace_premium

IEC 62053

Metering Accuracy

UL

Listed

Safety Standard

Ready to move forward with your next power project?

Our engineering team will review your technical requirements and provide the right solution.

Share your drawings or specifications to get a customized project proposal.

About the Power Meter

The digital power meter provides accurate measurement, reliable performance, and flexible functions for power monitoring and energy management.

Parameter Value
Power Supply
Power Supply 88-264V AC/DC, 48V/24V DC selectable, Power Consumption <4W
Voltage Input
Rating 100V, 380V (line voltage), 50Hz/60Hz
Measurement Range 1V-570V (line voltage)
Power Consumption <0.5VA per phase
Overload Capacity 1.4 times rated voltage, continuous operation; 2 times rated voltage, allowed for 10 seconds
Current Input
Rated Value (In) Phase Current 5A (1A Customizable), Neutral Current interpolate 1A
Measurement Range 0.04In to 20In
Power Consumption <1VA per Phase
Overload Capacity 2 times rated current, continuous operation; 10 times rated current, allowed for 10 seconds; 40 times rated current, allowed for 1 second
Measurement Accuracy
Measurement Accuracy Voltage/Current ±0.5%, Active Power ±1.0%, Frequency ±0.01Hz, Bidirectional Active Energy Class 1, Bidirectional Reactive Energy Class 2
Digital Output
Contact Capacity 5A continuous, 30A, 0.2s
Breaking Capacity DC resistive 50W, inductive 35W (L/R=0.04s); AC 1250VA, Maximum 5A
Digital Input
Digital Input Internal Excitation 24V DC
Environmental Conditions
Operating Temperature -25 ~ +70℃
Storage Temperature -40 ~ +85℃
Atmospheric Pressure 70 kPa~110 kPa
Above sea level ≤ 3000m
Electrical Insulation
Electrical Insulation In accordance with IEC 60255-5 (GB/T 14598.3); 2kV@1minute
Insulation Resistance In accordance with IEC 60255-5 (GB/T 14598.3); >100MΩ/500V AC
Electromagnetic Compatibility (EMC)
Electrostatic Discharge (ESD) Immunity Test Level 4
Fast Transient Burst (FTB) Immunity Test Level 4
Surge (Transient Overvoltage) Immunity Test Level 4

Product Overview

The GW-LR51-A Microcomputer Protection and Measurement Device is a new generation microprocessor-based relay protection equipment developed by our company to meet the requirements of power systems for relay protection.

It provides comprehensive protective functions for primary equipment such as lines, transformers, capacitors, and feeders at voltage levels of 35kV and below.

The device features high integration, comprehensive protection configurations, strong anti-interference capability, low power consumption, resistance to harsh environments, and convenient on-site maintenance and debugging.

It can be installed in switch cabinets in a distributed manner or mounted on panels. Both horizontal and vertical installation methods are supported to enhance panel space utilization.

Anatomy of Precision

Protection Functions

Current Protection: 50P-1/2/3, 50P, 51P, 50N, 51N, 46, etc.

Voltage Protection: 59PP, 27PP, LOP, etc.

Control & Monitoring: CT/Control Circuit Disconnection, DI Trip, etc.

Reclosing Control: 79 Auto-reclosing, SOTF AR, Standby Auto-injection Block, etc.

Logging & Time Synchronization Functions

Supports categorized query of 256 event records; data retained during power loss

Supports software time synchronization; internal clock error ≤ 1 s per 24 hours

Measurement Functions

Supports primary/secondary measurements

Supports forward/reverse active & reactive energy

Supports voltage, current, frequency, power, and power factor, etc.

Communication Functions

Standard 1× RS-485 communication interface (P1 port)

Supports Modbus-RTU industrial protocol

3 voltage inputs, 4 current inputs

11 DI, 5 DO

GR-LR51-A is widely applicable in construction and infrastructure, power distribution, industrial and manufacturing, and renewable energy sectors, supporting distributed generation integration, microgrid control, and power system protection and monitoring, enabling safe, efficient, and intelligent management of critical equipment and grid operations.


Cutout Dimensions and Installation Diagram (Unit: mm)

158a3dff8a6add214e9b0ea3de7a2552.png

ced38ece5959ca6d5e77be0c023961bc.png

Related Products

VoltMeter Mini product example image
New

VoltMeter Mini

Compact DIN-rail single phase meter for residential use.

View Product arrow_forward
Comms Hub X2 product example image

Comms Hub X2

Industrial IoT gateway for multi-meter data aggregation.

View Product arrow_forward
CT Sensor Pack product example image

CT Sensor Pack

High-precision current transformers split-core design.

View Product arrow_forward
Remote Display product example image

Remote Display

External LCD panel for cabinet door mounting.

View Product arrow_forward

Ready to upgrade your infrastructure?

Contact our sales team for bulk pricing or request a demo unit to test in your facility.